120°C Water Source High-Temperature Industrial Heat Pump

Classification: Steam Heat Pump

The Shenling 120°C Water Source High-Temperature Industrial Heat Pump reclaims low-grade heat from industrial effluent and wastewater—such as run-off from food processing, brewing, and pharmaceutical facilities—and elevates it to high-grade thermal energy. Outputting hot water at 100°C to 120°C, it provides a direct, highly energy-efficient alternative to traditional gas or electric boilers.

120℃ Very High Temperature Water to Water Steam Heat Pump

Description

The Shenling 120°C Water Source High-Temperature Industrial Heat Pump reclaims low-grade heat from industrial effluent and wastewater—such as run-off from food processing, brewing, and pharmaceutical facilities—and elevates it to high-grade thermal energy. Outputting hot water at 100°C to 120°C, it provides a direct, highly energy-efficient alternative to traditional gas or electric boilers.

770x483

Product Features

  • 48x48

    Achieves outlet water temperatures of 85°C to 120°C while processing waste heat inlet source temperatures between 45°C and 85°C.

  • 48x48

    Utilizes high-temperature hot water energy storage to run during off-peak power hours, reducing operational load during peak tariff periods.

  • 48x48

     Delivers a Coefficient of Performance (COP) up to 4.10, substantially cutting overall energy consumption.

  • 48x48

    Features a 7-inch touchscreen controller with a user-friendly interface for continuous operating parameter monitoring.

  • 48x48

    High Adaptability

  • 48x48

    Intelligent Control

Specification

Parameter Sub-Parameter Unit LSQR110FA-GRS LSR500FA-GRS LSR1000FA-GRS
Performance Parameters Heating Capacity kW 107.4 496.3 970.6
  Power kW 26.2 123.7 241.9
  COP kW/kW 4.1 4.01 4.01
Power Supply Power Supply Type / 3N~380V 50Hz
  Max Operating Current A 60 302 562
Operating System     Medium-Temperature LCD Display
Compressor Type   Scroll Screw
  Start Method   Variable Frequency Y-Δ Start
  Quantity   1 1 1
Refrigerant Name   R245fa
  Flow Control   Electronic Expansion Valve
User Side Water Flow Rate m³/h 18.3 85.5 167.2
  Pipe Connection Size mm DN65 DN100 DN125
  Water Pressure Drop kPa 53 59 65
Heat Source Side Water Flow Rate m³/h 12.5 64.2 125.5
  Pipe Connection Size mm DN50 DN100 DN100
  Water Pressure Drop kPa 50 54 60
Dimensions & Weight Dimensions mm 2200×1500×1620 2500×1500×2200 3500×2250×2200
  Net Weight kg 750 4840 8300
  Operating Weight kg 800 5030 8620
           
📝 Notes:
All parameters are based on nominal operating conditions:
Heat source side inlet/outlet water temperature: 85/80°C
User side steam temperature: 135°C
Makeup water temperature: 85°C
Specific unit parameters shall be subject to the nameplate of the unit.
The unit heat exchanger is a plate-type heat exchanger with flange connections.
The above parameters are for standard models. For non-standard requirements, please contact Shenling Company’s business consultation.
Due to product improvements and optimizations, the above parameters may be subject to change. Please refer to the selection guide and actual product.

Product Details

Why Choose Shenling

Shenling positions itself as an expert in industrial thermal energy solutions, with a product system built around high-temperature heat pump innovation and industrial waste heat utilization.

  • Cost-Saving Partner

The brochure shows high-efficiency heat pump systems replacing electric heating and gas boilers, with strong energy-saving performance across multiple applications, including reported annual savings in the millions of RMB for specific projects.

 

  • Broad Temperature Coverage

The portfolio spans  85°C, 120°C, and 150°C output levels, enabling different factory processes to be matched with the right heat grade instead of forcing a one-size-fits-all system.

 

  • Flexible Heat Source Compatibility

Solutions are available for  air source and  water source scenarios, including industrial wastewater, cooling water, underground water, ground surface water, and other low-grade heat sources.

787x451
787x451

What are High Temperature Heat Pumps (HTHPs)?

High-temperature heat pumps (HTHPs) efficiently generate heat between 85°C and 150°C+ (up to 200°C) by upgrading industrial waste heat or using advanced refrigerants. They bridge the gap between traditional heat pumps and boilers, providing sustainable, high-grade heat for industrial processes (drying, steam) and high-temperature hydronic heating systems.

How does HTHPs work?

Heat pump technology is a technology that transfers heat energy from low-grade heat sources to high-grade heat sources, and is a key technology for future energy conservation and carbon reduction.

787x451

Product Video

Product FAQ

  • Q1

    What primary industrial processes benefit from this unit?

    It is ideal for recovering waste heat from food processing, brewing, traditional Chinese medicine manufacturing, and other chemical processing plants.

  • Q2

    Where can this heat pump be placed on site?

    Its compact footprint allows flexible installation inside equipment rooms, on rooftops, or in outdoor locations.

  • Q3

    What heat exchanger type and connection styles are implemented?

    The system uses plate heat exchangers with standard flange connections.

  • Q4

    How does the unit lower operational electricity costs?

    It integrates 120°C energy storage technology, enabling high-temperature water generation during off-peak electricity hours to save costs during peak periods.

  • Q5

    What types of compressors are used in these units?

    Depending on capacity requirements, models feature scroll compressors with inverter startup or screw compressors with star-delta startup.

  • Q6

    What is the Coefficient of Performance (COP) for this model line?

    The unit achieves a COP between 4.01 and 4.10 W/W under nominal operating conditions.

  • Q7

    What heating capacities are available across standard models?

    Standard models range from 107.4 kW up to 970.6 kW in nominal heating capacity.

  • Q8

    What eco-friendly refrigerant does the unit use?

    It operates using R245fa eco-friendly refrigerant.

  • Q9

    What is the required heat source inlet water temperature?

    The system operates effectively with waste heat source inlet temperatures ranging from 45°C to 85°C.

  • Q10

    What user-side outlet water temperature does this unit deliver?

    It produces high-temperature hot water ranging from 85°C to 120°C.

Become our distributor or OEM/ODM partner