Achieves outlet water temperatures of 85°C to 120°C while processing waste heat inlet source temperatures between 45°C and 85°C.
- Home
- Products
- Water Source Industrial Heat Pump
- Steam Heat Pump
- 120°C Water Source High-Temperature Industrial Heat Pump
120°C Water Source High-Temperature Industrial Heat Pump
Classification: Steam Heat Pump
The Shenling 120°C Water Source High-Temperature Industrial Heat Pump reclaims low-grade heat from industrial effluent and wastewater—such as run-off from food processing, brewing, and pharmaceutical facilities—and elevates it to high-grade thermal energy. Outputting hot water at 100°C to 120°C, it provides a direct, highly energy-efficient alternative to traditional gas or electric boilers.
Description
The Shenling 120°C Water Source High-Temperature Industrial Heat Pump reclaims low-grade heat from industrial effluent and wastewater—such as run-off from food processing, brewing, and pharmaceutical facilities—and elevates it to high-grade thermal energy. Outputting hot water at 100°C to 120°C, it provides a direct, highly energy-efficient alternative to traditional gas or electric boilers.

Product Features
-

-

Utilizes high-temperature hot water energy storage to run during off-peak power hours, reducing operational load during peak tariff periods.
-

Delivers a Coefficient of Performance (COP) up to 4.10, substantially cutting overall energy consumption.
-

Features a 7-inch touchscreen controller with a user-friendly interface for continuous operating parameter monitoring.
-

High Adaptability
-

Intelligent Control
Specification
| Parameter | Sub-Parameter | Unit | LSQR110FA-GRS | LSR500FA-GRS | LSR1000FA-GRS |
| Performance Parameters | Heating Capacity | kW | 107.4 | 496.3 | 970.6 |
| Power | kW | 26.2 | 123.7 | 241.9 | |
| COP | kW/kW | 4.1 | 4.01 | 4.01 | |
| Power Supply | Power Supply Type | / | 3N~380V 50Hz | ||
| Max Operating Current | A | 60 | 302 | 562 | |
| Operating System | Medium-Temperature LCD Display | ||||
| Compressor | Type | Scroll | Screw | ||
| Start Method | Variable Frequency | Y-Δ Start | |||
| Quantity | 1 | 1 | 1 | ||
| Refrigerant | Name | R245fa | |||
| Flow Control | Electronic Expansion Valve | ||||
| User Side | Water Flow Rate | m³/h | 18.3 | 85.5 | 167.2 |
| Pipe Connection Size | mm | DN65 | DN100 | DN125 | |
| Water Pressure Drop | kPa | 53 | 59 | 65 | |
| Heat Source Side | Water Flow Rate | m³/h | 12.5 | 64.2 | 125.5 |
| Pipe Connection Size | mm | DN50 | DN100 | DN100 | |
| Water Pressure Drop | kPa | 50 | 54 | 60 | |
| Dimensions & Weight | Dimensions | mm | 2200×1500×1620 | 2500×1500×2200 | 3500×2250×2200 |
| Net Weight | kg | 750 | 4840 | 8300 | |
| Operating Weight | kg | 800 | 5030 | 8620 | |
| 📝 Notes: All parameters are based on nominal operating conditions: Heat source side inlet/outlet water temperature: 85/80°C User side steam temperature: 135°C Makeup water temperature: 85°C Specific unit parameters shall be subject to the nameplate of the unit. The unit heat exchanger is a plate-type heat exchanger with flange connections. The above parameters are for standard models. For non-standard requirements, please contact Shenling Company’s business consultation. Due to product improvements and optimizations, the above parameters may be subject to change. Please refer to the selection guide and actual product. |
|||||
Product Details
Why Choose Shenling
Shenling positions itself as an expert in industrial thermal energy solutions, with a product system built around high-temperature heat pump innovation and industrial waste heat utilization.
- Cost-Saving Partner
The brochure shows high-efficiency heat pump systems replacing electric heating and gas boilers, with strong energy-saving performance across multiple applications, including reported annual savings in the millions of RMB for specific projects.
- Broad Temperature Coverage
The portfolio spans 85°C, 120°C, and 150°C output levels, enabling different factory processes to be matched with the right heat grade instead of forcing a one-size-fits-all system.
- Flexible Heat Source Compatibility
Solutions are available for air source and water source scenarios, including industrial wastewater, cooling water, underground water, ground surface water, and other low-grade heat sources.


What are High Temperature Heat Pumps (HTHPs)?
High-temperature heat pumps (HTHPs) efficiently generate heat between 85°C and 150°C+ (up to 200°C) by upgrading industrial waste heat or using advanced refrigerants. They bridge the gap between traditional heat pumps and boilers, providing sustainable, high-grade heat for industrial processes (drying, steam) and high-temperature hydronic heating systems.
How does HTHPs work?
Heat pump technology is a technology that transfers heat energy from low-grade heat sources to high-grade heat sources, and is a key technology for future energy conservation and carbon reduction.

Product Recommendation
Brochure
Product FAQ
-
Q1
What primary industrial processes benefit from this unit?
It is ideal for recovering waste heat from food processing, brewing, traditional Chinese medicine manufacturing, and other chemical processing plants.
-
Q2
Where can this heat pump be placed on site?
Its compact footprint allows flexible installation inside equipment rooms, on rooftops, or in outdoor locations.
-
Q3
What heat exchanger type and connection styles are implemented?
The system uses plate heat exchangers with standard flange connections.
-
Q4
How does the unit lower operational electricity costs?
It integrates 120°C energy storage technology, enabling high-temperature water generation during off-peak electricity hours to save costs during peak periods.
-
Q5
What types of compressors are used in these units?
Depending on capacity requirements, models feature scroll compressors with inverter startup or screw compressors with star-delta startup.
-
Q6
What is the Coefficient of Performance (COP) for this model line?
The unit achieves a COP between 4.01 and 4.10 W/W under nominal operating conditions.
-
Q7
What heating capacities are available across standard models?
Standard models range from 107.4 kW up to 970.6 kW in nominal heating capacity.
-
Q8
What eco-friendly refrigerant does the unit use?
It operates using R245fa eco-friendly refrigerant.
-
Q9
What is the required heat source inlet water temperature?
The system operates effectively with waste heat source inlet temperatures ranging from 45°C to 85°C.
-
Q10
What user-side outlet water temperature does this unit deliver?
It produces high-temperature hot water ranging from 85°C to 120°C.