Model | HPM-V60W/R3 | HPM-V90W/R3 | HPM-V120W/R3 | HPM-V150W/R3 | HPM-V120W/SR3 | HPM-V150W/SR3 | |||
Power Supply | V/Ph/Hz | 220-240/1/50 | 380-415/3/50 | ||||||
Heating1 | Capacity | kW | 6.45 | 9.00 | 12.00 | 15.00 | 12.00 | 15.00 | |
Rated Input | kW | 1.32 | 1.86 | 2.53 | 3.33 | 2.53 | 3.33 | ||
COP | / | 4.90 | 4.85 | 4.75 | 4.50 | 4.75 | 4.50 | ||
Heating2 | Capacity | kW | 6.65 | 9.00 | 12.00 | 15.00 | 12.00 | 15.00 | |
Rated Input | kW | 1.73 | 2.43 | 3.33 | 4.29 | 3.33 | 4.29 | ||
COP | / | 3.85 | 3.70 | 3.60 | 3.50 | 3.60 | 3.50 | ||
Heating3 | Capacity | kW | 6.30 | 9.00 | 12.00 | 15.00 | 12.00 | 15.00 | |
Rated Input | kW | 1.97 | 2.86 | 4.00 | 5.26 | 4.00 | 5.26 | ||
COP | / | 3.20 | 3.15 | 3.00 | 2.85 | 3.00 | 2.85 | ||
Cooling4 | Capacity | kW | 6.50 | 9.00 | 12.00 | 15.00 | 12.00 | 15.00 | |
Rated Input | kW | 1.31 | 1.91 | 2.61 | 3.57 | 2.61 | 3.57 | ||
EER | / | 4.95 | 4.70 | 4.60 | 4.20 | 4.60 | 4.20 | ||
Cooling5 | Capacity | kW | 6.00 | 9.00 | 12.00 | 14.00 | 12.00 | 14.00 | |
Rated Input | kW | 1.90 | 2.95 | 4.00 | 4.91 | 4.00 | 4.91 | ||
EER | / | 3.15 | 3.05 | 3.00 | 2.85 | 3.00 | 2.85 | ||
Seasonal space heating energy efficiency class6 | Outlet water temp. at 35℃ | / | A+++ | ||||||
Outlet water temp. at 55℃ | / | A++ | |||||||
Refrigerant | Type(GWP) | / | R290(3) | ||||||
Charged volume | kg | 0.6 | 0.85 | 1.2 | |||||
Sound power Level7(1m) | dB | 64 | 67 | 69 | 71 | 69 | 71 | ||
Sound pressure Level7(1m) | dB(A) | 50 | 53 | 55 | 57 | 55 | 57 | ||
Net dimension( W×D×H ) | mm | 1000*450*725 | 1080*520*857 | ||||||
Packaged dimension( W×D×H ) | mm | 1110*475*870 | 1180*560*1005 | ||||||
Net weight/Gross weight | kg | 75/89 | 104/120 | 115/131 | 124/140 | ||||
Water piping connection | mm | R1″ | R1-1/4″ | ||||||
Ambient temp. range | Cooling | ℃ | -5~43 | ||||||
Heating | ℃ | -25~35 | |||||||
Domestic hot water | ℃ | -25~43 | |||||||
Outlet water temp. setting range | Cooling | ℃ | 5~25 | ||||||
Heating | ℃ | 25~75 | |||||||
Domestic hot water | ℃ | 20~70 | |||||||
Backup electric heater8 | Optional installation | kW | 3/9 | 3/9 | 3/9 | 3/9 | 3/9 | 3/9 | |
Capacity steps | / | 1/3 | 1/3 | 1/3 | 1/3 | 1/3 | 1/3 | ||
Power Supply | 3kW | V/Ph/Hz | 220-240/1/50 | ||||||
9kW | 380-415/3/50 | ||||||||
Notes: 1.Outdoor air temperature7℃ DB,6℃ WB;Water inlet 30℃,Water outlet35℃; 2.Outdoor air temperature7℃ DB,6℃ WB;Water inlet 40℃,Water outlet45℃; 3.Outdoor air temperature7℃ DB,6℃ WB;Water inlet 47℃,Water outlet55℃; 4.Outdoor air temperature35℃ DB;Water inlet 23℃,Water outlet18℃; 5.Outdoor air temperature35℃ DB;Water inlet12℃,Water outlet7℃; 6.Seasonal space heating energy efficiency class testes in average climate general conditions. 7.Testing standard: EN12102-1. 8.Backup electric heater is external installation. 9.Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02:2014. |
Get A Quote
R32 Domestic Air Source Heat Pump Water Heater
In today’s climate, where extreme weather patterns such as torrential rainfall are becoming more frequent due to climate change, it is essential to ensure that
On July 8, the Shunde District Housing, Urban-Rural Development, and Water Resources Bureau commended Guangdong Shenling Environment System Co., Ltd. (Shenling) for their exceptional Zero
On July 3rd, Shenling Deutschland GmbH (referred to as “Shenling Germany”) officially opened in Eschborn, Germany, and successfully held an opening ceremony.
How can we help you?