Model | LSQRF075PLH | LSQRF135PLH | LSQRF150PLH | LSQRF320PLH | ||
Heating(nominal) | Capacity | kw | 80 | 144 | 160 | 320 |
Power input | kw | 22.3 | 40.1 | 44.6 | 89.2 | |
Heating (low ambient temp.) | Capacity | kw | 59 | 104 | 118 | 236 |
Power input | kw | 21.8 | 38.4 | 43.5 | 87.0 | |
Cooling(nominal) | Capacity | kw | 76 | 135 | 152 | 304 |
Power input | kw | 21.9 | 38.9 | 43.6 | 87.6 | |
Power supply | 380V/3N-/50Hz | |||||
Maximum operating current | A | 54 | 94 | 100 | 200 | |
Refrigerant | / | R410A | ||||
Throttling device | / | Electronic expansion valve | ||||
Compressor | Type | / | EVI enhanced vapor injection compressor | |||
Quantity | / | 1 | 2 | 2 | 4 | |
Water-side heat exchanger | Type | / | Efficient vacuum brazing plate heat exchange | |||
water flow | m³/h | 13.1 | 23.2 | 26.1 | 52.3 | |
Unit water resistance | kPa | 45 | 40 | 48 | 40 | |
Water piping connection | inch | R1-1/2″ | R 2-1/2″ | R 2-1/2“ | R 3“ | |
Power cord | Live wire sectional area | mm² | ≥16 | ≥35 | ≥35 | ≥95 |
Live wire quantity | 3 | 3 | 3 | 3 | ||
Neutral wire sectional area | mm² | ≥16 | ≥16 | ≥16 | ≥50 | |
Neutral wire guanting | / | 1 | 1 | 1 | 1 | |
Earth wire sectional area | mm² | ≥16 | ≥16 | ≥16 | ≥50 | |
Earth wire quantity | / | 1 | 1 | 1 | 1 | |
Net dimension | LxWxH | mm | 1150×1100×2300 | 2200×1150×2100 | 2200×1150×2300 | 2490x2210x2600 |
Net Weight | kg | 450 | 930 | 950 | 1900 | |
Wired controller | / | PJAC-T-A301XY | ||||
Container loading quantity(40HQ) | pcs | 20 | 10 | 10 | 5 | |
Heating | Ambient temp. range | ℃ | “-26~30 | |||
Outlet water temp. range | ℃ | 30~55 | ||||
Cooling | Ambient temp. range | ℃ | 5~48 | |||
Outlet water temp. range | ℃ | 5~20 | ||||
●Nominal cooling capacity test condition: rated water flow rate at 0.172m³ /(h·kW), outlet water temperature at 7°C and outdoor ambient dry bulb temperature at 35°C. ● Nominal heating capacity test condition: rated water flow at 0.172m³/(h·kW), outlet water temperature at 45°C and outdoor ambient dry bulb/wet bulb temperature at 7/6°C. ● Low temperature heating capacity test condition: rated water flow at 0.172m³/(h·kW), outlet water temperature at 41°C and outdoor ambient dry bulb/wet bulb temperature at -12/-14°C. ● The performance may be adjusted due to product improvement without prior notice. Please refer to the nameplate for specific parameters. |
Get A Quote
KEYENERGY is the most important European event dedicated to technologies, services, integrated solutions for energy efficiency and renewable energies in Italy and the Mediterranean basin,
As the world transitions toward more sustainable heating and cooling solutions, heat pumps have become central to replacing fossil fuel-based systems. Their efficiency in reducing
During aircraft turnaround and parking, the Auxiliary Power Unit (APU) traditionally provides oxygen, monitoring, and maintenance. However, APUs are being gradually replaced by Bridge-Mounted Equipment
How can we help you?